General Considerations
Remove any stored items from the loft so you can work in a clean and uncluttered space. Try to work in good lighting and use a portable battery light if necessary. Measure your cold water tank so that you can fit an appropriate tank jacket. You’ll need to insulate tanks and pipes before you start to lay the loft insulation.

Before starting, make sure your loft has ventilation gaps at the eaves or is fitted with loft ventilation. Be sure to maintain this ventilation gap during and fter installation.

If you want to use the loft space to store items, install raised floor loft legs that you can fix boards to, above the insulation. Leave a minimum air gap of 50mm beneath the boards. Alternatively, cover an existing boarded area with insulation boards rather than insulation rolls.

Insulation shouldn’t be laid over any electric or high amperage cables. Ideally, cables should be clipped to the roof joists or gently lifted out of the way and then laid over the insulation once it is in position.

If you have recessed lights or downlighters, install down light protectors, being sure to follow the manufactureres instructions.

Do not fit insulation underneath the water tank unless it is in an elevated position.

Getting Started
Installing the Ezy Fit Green IWI system couldn’t be easier or faster, but with any loft system, preparation is key.

Start by lining your cold water tank with the jacket, following the manufacturers instructions, and insulate any pipes in the loft area with appropriate insulation.

Insulation shouldn’t be laid over any electric cables. Where possible, clip them to the roof joists or gently lift them out of the way whilst you install, before laying them over the insulation when its in position.

Electric cables give off heat when in use and should be routed where they will not be covered by thermal insulation, so the heat can be dissipated. If cables need to be located within insulation, they should be run in conduit and possibly increased in size. Advice on this should be sought from a qualified electrician. PVC-insulated cables should be located in suitable conduit to avoid being in direct contact with the EZY FIT insulation in order to prevent plasticizer migration which can cause loss of protection to the conductors.

If you have recessed lights or down lighters, install down light protectors, being sure to follow the manufactureres instructions. There should be measures taken to safeguard and prevent air leakage around the lights into the roof voids. These can be covered and sealed with fire rated hoods or caps.