Design Considerations
The Ezy Fit K Dry Insulated Dry Lining System is installed using various adhesives and/or can be mechanically fixed, either directly onto the wall or onto the timber battens or metal furring (see the Installation part of this design guide). The system is for use as adding insulation to masonry (solid and cavity) walls and the underside of timber or steel rafters in pitched roofs, in existing and new dwellings and buildings of similar occupancy and in non-load bearing partitions.
The foil bonded to the plasterboard provides the integral vapour check for the system, it is recommended that services which penetrate the dry lining, e.g. light switches, and power outlets, are kept to a minimum to limit damage to vapour checks.
Masonry Walls
The system may be installed on masonry construction including clay and calcium silicate bricks, concrete blocks, and natural and reconstituted stone blocks. Since adding insulation on the inside of a property is not intended to resist rain penetration, walls that are to be insulated must already be rain resistant from the outside of a property and show no signs of water ingress. If present, mould, or fungal growth should be treated prior to the application of the system.
With an internal wall insulation system that forms a void of 25 mm or more services can be incorporated behind the internal wall insulation, making the chasing of the wall unnecessary. Where the services have a greater depth than the void, the wall should be chased rather than the insulation. Suitable isolation methods, such as a conduit or capping, must be used to ensure cables do not come into contact with the insulation The installation of an internal wall insulating system requires careful detailing around doors and windows to achieve a satisfactory surface for finishing. In addition, every attempt should be made to minimise the risk of thermal bridging at reveals and where heavy separating walls are attached to the external wall. New work must be designed to accommodate the thickness of the insulation system, particularly at reveals, heads, and sills and in relation to ceiling height. Where the dimensions of fixtures are critical (e.g. bathrooms), these should be checked before installation.
Pitched Roofs
Pitched roofs should be designed and constructed in accordance with BS 5534 : 2003 (see sections 16.6 to 16.10) and incorporate normal precautions against moisture ingress.
In tiled or slated pitched roofs designed and constructed as above, the system is suitable for use beneath the rafters in conjunction with a BBA-approved breathable membrane and, when necessary, a VCL.