Generic filters
Filter by Categories
Get a quote

Guides and datasheets

Introduction

Specification

Last updated August 2026

The Ezy Fit K Dry Insulated Dry Lining System comprises of Kooltherm rigid phenolic board faced on one side with a perforated foil and on the other with an unperforated foil which is bonded to the plasterboard. The system is for use as an insulating dry lining to masonry (solid and cavity) walls and the underside of timber or steel rafters in pitched roofs, in existing and new dwellings and buildings of similar occupancy.

Table 1 Nominal Characteristics

Characteristic (unit)Value
Length (mm)2400
Width (mm)1200
Insulation thickness (mm)25 to 80
Thickness of plasterboard (mm)12.5
Weight of plasterboard (kg)24
Edge ProfileTapered

Table 2 Example U values for walls and sloping sides of the pitched roof

Board thickness (mm)Phenolic Foam ThicknessAdhesively Fixed
(Dots & Dabs)
Mechanically FixedU Value for lining to pitched roofs
32.5200.530.560.75
42.5300.410.460.61
52.5400.330.390.51
62.5500.280.340.44
72.5600.240.300.38
82.5700.220.270.34
92.5800.190.240.30