Residual Loft Space

Gable Wall, Party Wall or Masonry Dwarf Wall

Last updated August 2026

  1. Position M IWI slab into place on the substrate
  2. Drill 8mm diameter pilot holes through the insulation into the substrate, one to each corner of each slab or section, a maximum of 100mm from slab edges.
  3. Fix M IWI Slab to the substrate with 130mm M IWI Fixings, using a hammer, through the predrilled holes.
  4. Minor deviations in wall level can be overcome using more fixings to ensure M IWI slab is in contact with the entirety of the surface beneath.
  5. Slabs should be fixed close butted and staggered at both horizontal and vertical joints.
  6. Care should be taken to ensure that edges of the slabs will not coincide with the edges of the plasterboard once fixed. Ensure slabs are accurately scribed at all wall junctions with all
    element planes to ensure a tight fit.
  • Fix the plasterboard to the entire face of M IWI slabs, using a minimum 150mm fixings at maximum 600mm centres within the field of the board and at a maximum distance of 100mm from board edges.
  • Plasterboard fixed direct through the M IWI slabs into the substrate and countersink fixings into plasterboard.
  • Ensure any wiring for electrical outlets is fed through pre-drilled holes. Fit any back boxes into place and rewire electrical outlets.
  • Ensure all edges are sealed correctly using the High Mortality M IWI Blue seal
  • Ensure the head of the fixings are covered with scrim tape & a full skim of plaster (at least 5mm), re-fit or replace skirting boards and radiators as necessary, using appropriate anchor fixings
  • Ensure Plasterboard installed adheres to all regulations (BS EN520) and installed in accordance to BS8212:1995