Generic filters
Filter by Categories
Get a quote

Guides and datasheets

Introduction

Last updated September 2026

The EZY-FIT Under Floor Insulation System is designed specifically for use with suspended timber floors. The EZY-FIT UFI Glass Mineral Wool Roll is installed between the timber joists, from below, and securely held in place through the use of EZY-FIT Insulation Support Netting tacked to the underside of the joists.

Note: Any deviation away from the above style of construction within a property is NOT covered in the following guidance notes. Please contact our technical department for further advice via support@ezy-fit.co.uk. The EZY-FIT Underfloor Insulation System comprises of EZY-FIT UFI Rolls which are non-combustible Glass Mineral Wool rolls, designed specifically for use under suspended timber floor applications where access from below the floor is provided.

The Ezy-Fit UFI System is designed to be installed in accordance with BEIS Best practice Guidance. In older houses underfloor areas are usually un-insulated, thus allowing significant heat loss through the floor and into the void beneath.

The friction fitting of mineral wool insulation between the timber joists closes any joints, reducing the potential for gaps and unwanted loss of thermal performance. The flexible nature of the mineral wool insulation accommodates for movement in floors ensuring all joints remain closed.

Application is to be carried out from the underside of the floor joists, meaning there is no requirement for the floor boards to be removed and replaced. Where a cellar is present within the property, fire protection must be carried out strictly in accordance with Building Regulations Approved Document B. Existing ventilation must be present to the under-floor void and any insulation installed must not obstruct or interfere with the flow of ventilation.

Where application is carried out from under the floor, a sufficient and safe working space must be available, either by using the crawl space underneath the insulation, or where access can be gained to fit the insulation into place and then secured using insulation support netting. The health and safety of the installers should be carefully considered to ensure a safe working space, given that they may be working in enclosed spaces, with potential exposure to toxic materials or substances in the ground. The suitability of PPE should also be considered.

Training is available on request enabling applicators to become fully carded EZY-FIT Recognised Contractors and to meet PAS2030 and technical monitoring compliance requirements.

Working Conditions
It may be necessary to test the air on occasions, to check that it is free from both toxic and flammable vapours and that the air is fit to breathe, particularly when insulating underneath old cellars. Testing should be carried out by a competent person using a suitable gas detector which is correctly calibrated.

Floor Construction
Suspended timber ground floors consist of the finished timber floorboards being attached to floor joists, which are suspended above the sub-floor of the foundation. These floor joists are raised above the sub-floor on small supporting walls called tassel walls (or sleeper walls).