Pre Installation
In line with PAS requirements, an initial survey is required to confirm the condition of the under floor and suitability for the UFI system to be installed.
We must stress the importance of taking your time and completing the initial survey correctly, accuracy will help the Installation team and the Customer receive the best experience
All pre-installation surveys and assessments must be completed in accordance with the PAS to which the installer is claiming compliance
Before installing UFI, it is essential that the condition of the void and floor structure is thoroughly assessed, covering the risks identified in table 3 of BEIS Document: Guide to Best Practice – Retrofit Floor Insulation – Suspended Timber Floors.
Any defects should be rectified before work commences or as part of the agreed works with the customer. Any remediation work must be carried out before the installation of the UFI.
Particular emphasis should be made for the below risks:
- Condition of the floor structure, ensuring it is free from rot (dry rot and wet rot), especially at the abutment to any external walls, tassel or dwarf walls.
- Evidence of existing dampness, staining or condensation on the faces of the floor.
- Evidence of infestation (bore holes or active infestation).
- The type, suitability and condition of floor timbers, substrates and any openings.
- The type and condition of floorboards or breather membrane present.
- Room space ventilation requirements.
- Please note: For the avoidance of doubt within the Best practice guidance
- The resulting height of the void allows for sufficient air movement post-installation (150mm minimum) between the lowest level of either the insulation or the floor joist. It is essential to check the condition and power rating of existing cabling beneath the ground and underside of floor which may need to be repositioned/replaced or extended beneath the insulation or timbers-
- Generally, the following provides an indication of the floor configurations that may be more at risk from cold bridging:
- 8-inch joist (200mm) the U-value will not exceed 0.7 and is therefore highly unlikely to be an issue.
- 6-inch joist (150mm) is also unlikely to create an issue (other than in extreme situations where original hardwood joists and floorboards remain).
- 4-inch joist the U-value is likely to exceed 0.7W/m2k, and therefore Building Regulations will not be satisfied.
Managing Services
- Services must be surveyed and treated to ensure compliance with building regulations.
- Water pipes should be insulated appropriately with foam pipe insulation.
- Gas pipes should not insulated and must remain in a ventilated space.
- Electrical wiring must not be covered with insulation and should be safeguarded by an appropriate shield or restrictor.
- Flues must be safeguarded and insulation must not restrict the performance.