Ventilation & Damp
Air from the outside can and should flow under suspended timber floors, and this would typically be through air bricks or grilles in the outer walls. Free flowing air can help to maintain a healthy environment for the timber floor construction. However, if there are gaps in the floor covering, or the floor is not insulated, air can penetrate the floor structure and make the internal habitable rooms harder to keep warm.
A damp-proof course separates the wall plates from the tassel walls, preventing decay from any rising moisture. It is usual to have gaps in the block work of the tassel/sleeper walls, ensuring adequate air circulation. If the installation of UFI results in this cross-ventilation being reduced or restricted, then an equivalent ventilation provision should be provided by – for example; the removal of bricks, provision of an additional external vents, or tapering of the insulation to maintain the original ventilation rate. Careful consideration should be given to insulating properties where there is currently no DPC, with appropriate risk analysis undertaken ensure no unintended consequences occur. The addition of underfloor insulation should not proceed if it would bridge the DPC level.
Vents must be installed in the opposing external walls to ensure that adequate cross-ventilation is given to the timbers, ensuring the circulation of fresh air, keeping the timbers dry and preventing decay. Where tassel walls are present, they typically include gaps in the block work to ensure adequate air circulation.
These vents should be adequately sized for the property (in line with Part C of the Building Regulations). In addition, they should be free from dirt, dust and other impediments. The minimum size for airbricks should be 1500mm2 per meter run of external wall or 500mm2 of floor area, whichever is the greater.
The ventilation provision to the main dwelling should be assessed to ensure that the building will not become less compliant than before the measure was considered for installation. This assessment should be undertaken in line with the requirements of the latest version of PAS2035 for fabric improvement measures (also see previous comments regarding PAS2030 requirements).
Building Regulation Compliance – U-Values
To improve the thermal performance of a suspended timber floor by adding extra insulation to a floor, it will need to comply with the current relevant national building regulations. Currently, In England, Wales and Northern Ireland, the floor should achieve a thermal transmittance (U-value) of at least 0.25 W/m2K. In Scotland the floor should achieve a thermal transmittance (U-value) of at least 0.18 W/m2K. To achieve this standard, please refer to the manufacturer’s guidance for this level of performance, although this may vary depending on the floor type, shape and size. In all circumstances, the area weighted U-value must be calculated in accordance with the conventions in the current version of BR443 conventions for calculating U-values.
Cold Bridging
Generally, the following provides an indication of the floor configurations that may be more at risk from cold bridging:
- 4-inch joist the U-value is likely to exceed 0.7W/m2k, and therefore Building Regulations will not be satisfied.
- 6-inch joist (150mm) is also unlikely to create an issue (other than in extreme situations where original hardwood joists and floorboards remain).
- 8-inch joist (200mm) the U-value will not exceed 0.7 and is therefore highly unlikely to be an issue.
- Use full depth strutting between the joists at the perimeter of the floor to provide a fixing for the flooring and to limit the size of gaps which need to be sealed at the edge of the floor.
- Seal the skirting to the wall with a sealant or airtightness tape, and to the floor with a flexible sealant, airtightness tape, or an extruded draughtproofing section. Also seal the gaps at services penetrations and access panels in the flooring with airtight gromets (if possible) or flexible sealants.
- Pack the space between the wall and the joist or solid strutting with mineral wool insulation.
- Apply a continuous seal in the space between plasterboard dry lining and masonry walling. This can be undertaken using tapes and other physical barriers or use of tapes and membranes if the substrate can be clean, dry and free from debris, particularly at skirting level.
- Position the insulation level with the top of the joists to avoid any air movement between the insulation and the flooring. This may be less critical where the movement of cold air from the sub-floor space through or around the insulation, is restricted.
- Choose a support method which ensures that the full thickness of insulation is maintained for the full width between the joists. Support quilt insulation to reduce air movement through and above the insulation, via a substantial netting – netting must provide a minimum 25-year guarantee. The insulation support netting is to be securely held in place by fixing appropriate galvanised staples to the underside of the joists.
EZI-FIT Under Floor Insulation Roll Product Details
| Insulation Thickness: | 150mm |
| Roll size: | 1.2m (2 x 600mm or 3 x 400mm) x 4.55m |
| Area per roll: | 5.46 m2 |
| Thermal Conductivity: | 0.040 W/mK |
| Vapour Resistivity: | 5.00MNs/gm. |
| Facing: | Unfaced |
| Minimal Density of Insulation: | 10.5 kg/m3 |
| Euro class Reaction to Fire Classification (to BS EN 13501-1): | A1 |
| BRE Green Guide Rating: | A+ |